Chlorination and De-chlorination of Water System
Chlorination and De-chlorination of Water System
Effective concentration of chlorine and chlorination and de-chlorination of water system using Sodium hypochlorite and Sodium meta bisulfite
Purified water is a basic requirement of any pharmaceutical company. Generally the source of raw water remains a bore well and raw water is stored in a storage tank. This raw water is stored for several days. These storage tanks are not cleaned for many days. Due to these situation problem of microbial growth would occur in raw water storage tank and contaminate the whole water system.
This is a common problem in pharmaceutical industries and generally solved by chlorination of the water storage tank. Sodium hypochlorite is used for chlorination of water. When sodium hypochlorite is dissolved in water is gives free chlorine that forms hypochlorous acid which actively takes part intensification process.Cl2+ H2O → HOCl + HCl
Chlorine is a strong oxidizing agent that oxidizes organic compounds effectively.Hypochlorous acid is neutrally charged molecule that easily penetrates into the negatively charged pathogen cell wall and reacts with the lipids of cell wall and enzymes and proteins within the cytoplasm of cell making them nonfunctional. Due to this the growth of organism is inhibited and organism dies or does not reproduce further.Concentration of chlorine in water and contact time plays a significant role in water disinfection. A 5 ppm concentration of chlorine in water is effective. It takes 15-30 minutes to kill all the pathogens in water.
Quantity of Sodium hypochlorite to be added in water tank can be calculated by following formula:Volume of sodium hypochlorite =Volume of waterx required concentration in PPM1000000x %age of chlorine in Hypo Example: FLOW(m3/h)×requrid PPM × HOURS
-----------------------------------------------------------
10× CONCENTRATION OF CHEMICAL
All molecules of added chlorine do not react with the organic matter of raw water but excess of the chlorine remains in water in active form. This active chlorine is corrosive in nature and damages the RO membranes and ion exchange resins of water purification systems.
Drinking water should not contain more than three ppm of free chlorine. So removal of this chlorine is necessary before this water is treated by resins and reverse osmosis membranes.There are various methods to remove the chlorine residues from the water before the water treatment. As far as ultra violet light also helps to remove the chlorine but it does not seem too effective and needs chemical neutralization of chlorine also. Sodium thiosulfate and sodium metabisulphite are generally used for this purpose. These methods can cause scaling in RO
membranes there after efficiency of RO system can be reduced.Sodiumthiosulfateis found in the form of colorlesscrystals and reacts with chlorine as a reducing agent. Reaction of sodium thiosulfate with hypochlorous acid produces sodium sulfate and hydrochloric acid.Na2S2O3+4HOCl + H2O→2NaHSO4+4HClThe required amount of sodium thiosulfate may vary according to the pH of the water.Sodium metabisulphite is a widely used white powder for the removal of chlorine from water system. It produces sodium bisulfate and hydrochloric acid with the reaction of hypochlorous acid.Na2S2O5+ 2HOCl + H2O→2NaHSO4+2HClThe required amount of the sodium metabisulfite can be calculated. Approximately 3 ppm of sodium metabisulfite is required to neutralize the 1 ppm of free chlorine.Therefore the chlorination and de-chlorination both are essential part of water purification system and both of these should be done effectively during the water purification. De-chlorination byultraviolet lightis safer becauseit does not create the de-chlorination by products, those are harmful for human. But due to more practical approaches, de-chlorination by chemical methods is being done widely in pharmaceutical industrie
Effective concentration of chlorine and chlorination and de-chlorination of water system using Sodium hypochlorite and Sodium meta bisulfite
Purified water is a basic requirement of any pharmaceutical company. Generally the source of raw water remains a bore well and raw water is stored in a storage tank. This raw water is stored for several days. These storage tanks are not cleaned for many days. Due to these situation problem of microbial growth would occur in raw water storage tank and contaminate the whole water system.
This is a common problem in pharmaceutical industries and generally solved by chlorination of the water storage tank. Sodium hypochlorite is used for chlorination of water. When sodium hypochlorite is dissolved in water is gives free chlorine that forms hypochlorous acid which actively takes part intensification process.Cl2+ H2O → HOCl + HCl
Chlorine is a strong oxidizing agent that oxidizes organic compounds effectively.Hypochlorous acid is neutrally charged molecule that easily penetrates into the negatively charged pathogen cell wall and reacts with the lipids of cell wall and enzymes and proteins within the cytoplasm of cell making them nonfunctional. Due to this the growth of organism is inhibited and organism dies or does not reproduce further.Concentration of chlorine in water and contact time plays a significant role in water disinfection. A 5 ppm concentration of chlorine in water is effective. It takes 15-30 minutes to kill all the pathogens in water.
Quantity of Sodium hypochlorite to be added in water tank can be calculated by following formula:Volume of sodium hypochlorite =Volume of waterx required concentration in PPM1000000x %age of chlorine in Hypo Example: FLOW(m3/h)×requrid PPM × HOURS
-----------------------------------------------------------
10× CONCENTRATION OF CHEMICAL
All molecules of added chlorine do not react with the organic matter of raw water but excess of the chlorine remains in water in active form. This active chlorine is corrosive in nature and damages the RO membranes and ion exchange resins of water purification systems.
Drinking water should not contain more than three ppm of free chlorine. So removal of this chlorine is necessary before this water is treated by resins and reverse osmosis membranes.There are various methods to remove the chlorine residues from the water before the water treatment. As far as ultra violet light also helps to remove the chlorine but it does not seem too effective and needs chemical neutralization of chlorine also. Sodium thiosulfate and sodium metabisulphite are generally used for this purpose. These methods can cause scaling in RO
membranes there after efficiency of RO system can be reduced.Sodiumthiosulfateis found in the form of colorlesscrystals and reacts with chlorine as a reducing agent. Reaction of sodium thiosulfate with hypochlorous acid produces sodium sulfate and hydrochloric acid.Na2S2O3+4HOCl + H2O→2NaHSO4+4HClThe required amount of sodium thiosulfate may vary according to the pH of the water.Sodium metabisulphite is a widely used white powder for the removal of chlorine from water system. It produces sodium bisulfate and hydrochloric acid with the reaction of hypochlorous acid.Na2S2O5+ 2HOCl + H2O→2NaHSO4+2HClThe required amount of the sodium metabisulfite can be calculated. Approximately 3 ppm of sodium metabisulfite is required to neutralize the 1 ppm of free chlorine.Therefore the chlorination and de-chlorination both are essential part of water purification system and both of these should be done effectively during the water purification. De-chlorination byultraviolet lightis safer becauseit does not create the de-chlorination by products, those are harmful for human. But due to more practical approaches, de-chlorination by chemical methods is being done widely in pharmaceutical industrie
Comments
Post a Comment