Requirement of Active and Passive Air Sampling in Controlled Areas

Air sampling is a mandatory procedure to be followed in pharmaceuticals to produce the contamination free quality product.

What would you say if I ask for the causes the most contamination of products during the manufacture of pharmaceuticals?

However, air is another keysource of contaminationthat most pharmaceutical facilitiesoften ignore to take precaution from. Air samplingor air monitoring is essential for Quality Control(QC) purposes especially in companies that manufacture pharmaceutical products in controlled areas or clean rooms with filtered air.Well, what pharmacists, health care practitioners, and microbiologists refer to as air sampling can simply be defined as taking a correct measurement of the practical airborne bacteria, mold, yeast, spores and fungal cells which can be collectively referred to as bioburden in the surrounding air.
The two main methods used to sample air are:
1.Active air sampling/ monitoring

2.Passive air sampling/ monitoring

1. Active Air Sampling

This method is sometimes referred to as pumped sampling where the air in the controlled area is kinetically monitored during manufacturing. What this means is, over a specific time period, a microbial air sampler is used to continuously force an already established volume of air to passover a petri dish that serves as the artificial medium containing an agar nutrient based test media
The Petri dishes containing medium are then removed from the air sampler and directly incubated. Incubation allows the collected culture that is the microorganisms such as bacteria, fungietc to grow into visible colonies that can be easilyidentified and analyzed through counting. This gives a clear indicator of how many viable microorganisms are there per cubic meter of air.

Advantages
*.It allows for both qualitative and quantitative analysis of the sample
*.Allows for faster results as devices used for thismethod allow for a shorter sampling period suchas 10 minutes
*.Ideal for controlled areas as they tend to have a low microbial concentration

2. Passive Air Sampling

Also referred to as diffusive air sampling, passive air sampling basically involves leaving settle plates or contact plates exposed to the air for a certain period of time to collect microbes that may settle onto the surfaces of the plates.Just like in the active air sampling, the plates are then incubated to allow for the microorganisms that dropped onto the plates to grow into coloniesthat can accurately be analyzed.

Advantages
*.For starters, the method is inexpensive as it does not require a lot of equipment
*.Offers average contamination levels over long sampling periods that could range from hours tomonths
*.No supervision is required during the sampling period
*.Its affordability makes it easy to sample various contamination hotspots at once

Both methods have their own advantages but none of the methods of air sampling given above is optional butboth are mandatorybecause both of them give different information about the air in theclassified area.

As I mentioned above in active air sampling we determine bioburden in 1 cubic meter area and wesample 1000 liters of air by air sampler while in passive air sampling we determine that how much microbes settle in 90 mm diameter surface of anyequipment exposed in controlled area.

A lot of pharmaceutical professionals have confusion in air sampling that which one should be done among both of samplings. But all regulatory guidelines say that it is mandatory to sample and analyze the clean room area by both methods of air sampling.

Comments

Popular posts from this blog